Question

What is a vapour barrier and which side does it go on?

Vault Verified
Curated Intelligence
Definitive Source
Answer

A vapour control layer (VCL), often called a vapour barrier, is a membrane restricting water vapour from passing through a building element into the insulation and structure behind it.

Why it exists. Warm indoor air holds far more moisture than cold air. That vapour migrates through walls, floors and roofs toward the colder outside. If it reaches a point cold enough for it to condense — inside the insulation or against a cold surface within the construction — you get interstitial condensation: hidden damp, degraded insulation performance, rot in timber and corrosion in fixings, all invisible until serious.

The rule for which side. The vapour control layer goes on the warm side of the insulation — the inside face in a UK climate. This stops moisture entering the construction in the first place.

The corresponding principle for the outside is that the construction should get more vapour-open toward the outside, so any moisture that does get in can escape rather than being trapped. The shorthand is "vapour tight inside, vapour open outside".

Getting it backwards is worse than omitting it, because a barrier on the cold side traps moisture inside the construction with no route out.

Where it matters most: internal wall insulation, warm-roof loft conversions, timber frame construction, and insulated floors.

Vapour barrier is not the same as a breather membrane. A breather membrane goes on the cold side, keeps liquid water out while allowing vapour to escape — the opposite specification, and the two are routinely confused on site.

Airtightness matters as much as the membrane. Most moisture reaches a construction by air movement through gaps rather than by diffusion through materials. A perfect membrane with unsealed penetrations at sockets, pipes and junctions does little. Tape joints and seal penetrations.

Ventilation is the other half. Restricting vapour into the structure means it stays in the room, so extraction and background ventilation must handle it.

Get a specific design for anything complex — this is where retrofits fail.